Energy Meter Test Bench

Energy Meter Test Bench
Product name : Energy Meter Test Bench
Item : PEC-T-ZDDA-16
Details :
PEC-T-ZDDA-16 is specially designed for collector and concentrator of LV reading system to measure comprehensive errors. It can be utilized in labs to measure and evaluate functions, performances and field applicability of various electrical instruments.
It is applicable to factory testing (for LV reading system collector and concentrator manufacturers), product test before acceptance (for electrical measurement management institutes), and product examination (for lab of power institute).
It is a combination of controlling cabinet, measuring desk and application software. The whole system is consisted of programmable power source, multi function reference standard meter, meter holding table, GPS clock time source, communication ports, measuring ports, display/indication equipment, power loss measurement equipment, function simulators, auxiliary power supply, working station (PC, printer, barcode scanner) etc.
 
Main features:
Ÿ   Single testing mode and automatic testing mode for selection
Ÿ   Measurements of working power:
-        Power on
-        Power on self check and self recover
-        Power on initialization
-        Open phase
-        Rated voltage and permissible deviation
-        Static power loss
-        Power-off data and clock retention
Ÿ   Function measurements:
-        Tests for data collection (power line carrier collection mode configured, other modes for selection):
* Data collection via RS 485 bus
* Data collection via power line carrier
-        Data store and management
-        Parameter setting and data querying
-        Events recording
-        Data transmission (GPRS mode preset, other modes optional)
* Data uploaded via network channel
* Data uploaded via RS485 channel
* Data uploaded via RS232 channel
* Data uploaded GPRS channel
* Data uploaded via CDMA channel (optional)
* Data uploaded via 230M wireless power network
* Data uploaded via PSTN channel
-        Maintenance and exploration of local ports
-        Remote upgrade
Ÿ   Carrier communication capability measurements:
-        Maximum emission level
-        Sensitivity of receiving
-        Central frequency
Ÿ   Measurements of data collection reliability:
-        Accuracy
-        Success rate
Ÿ   EMC test
Voltage dip and short interruption
Ÿ   Optional functions (Kehui’s patents):
-        Simulation tests:
* Influence of interferences from popular appliances
* Influence of impedance changes
* Influence of reactive power compensation
* Influence of repeater
* Load capacity of RS 485 port (of collector and concentrator)
* Receiving sensitivity of RS 485 port (of collector and concentrator)
* RS 485 bus wiring length simulation test
-        Immunity of frequency magnetic field test (via Kehui’s frequency immunity tester for collection terminal)
Technical data

General
 
Accuracy class of reference meter
0.05
Testing positions
16 (with automatic current short connection holder)
Downstream RS 485 bus
1~3 lines
Virtual energy meter RS 485 bus
1-2 lines
Intrinsic error of reference clock time source
≤±0.5×10-6
Size (L×W×H, mm)
Measuring desk: 2130×1850×650
Controlling cabinet: 600×800×1800
Three phase power source
 
Output voltage
3×100V, 3×57.7/100V, 3×220/380V ±20%
Output current
0.01A~25A
Output capacity
Voltage: 15VA/position
Current: 25VA/position
DC analogue quantity
4~20mA
Communication of master station (via)
 Network, GPRS, SMS(optional)
Local ports
IR, RS 232, RS 485, Pulse, alarm, switching value,  wheel control, gate node