Portable Energy Meter Test System with Integrated Voltage and Current Source

Portable Energy Meter Test System with Integrated Voltage and Current Source
Product name : Portable Energy Meter Test System with Integrated Voltage and Current Source
Item : PEC-A
Details :
Main Features:
·           Accuracy class: 0.05%
·           Measurement of errors for various induction and static energy meters (three phase three wire, three phase four wire, and single phase); Simultaneous measurement of errors for active and reactive  (true) energy meters in a loop; simultaneous measurement of errors of master and sub meter in a loop; proofreading of constant for various energy meters
·           Comparison measurement of voltage, current, power, power factor, phase and frequency of electrical instruments and transmitters
·           Measurement of transformation ratio for CT
·           Dynamic measurement and simultaneous display of three phase voltage, current, power, power factor, phase, frequency, and vector diagram etc.
·           Proofreading of constant by measuring pulse number, time, and value of power; dial measurement according to number of KWh, time and number of pulse; preset number of KWh, the dial will stop accordingly; automatic measurement for register
·           Measurement of harmonics of voltage and current (2nd ~51st ), measured data can be stored
·           Simultaneous measurement of three phase voltage and current, displayed in waves
·           Meter reading for multi function energy meter
·           Source integrated
·           GPS reference clock integrated, time pairing for energy meters
·           Any power factor and current outputs, fully measurement for measuring points
·           Detection of wiring failures for three phase wire circuit(48), three phase four wire circuit(96), four quadrant electrical measurement , displayed in hexagon diagram;
·           Data management:
-       Measured data can be stored and downloaded via a flash disk or RS232 communication port
-       Measured data of 1500 energy meters can be stored including operating parameters for further analysis
-       Communicable to PC, convenient connection to existing data base and management system; PEC Energy Meter Management System software is provided (optional)
-       Management software can be upgraded at anytime
·           Protection and alarm of voltage short circuit and current open circuit; faults and relevant phase sequence can be displayed and voice reminded
·           Measurement of electricity compensation
·           With high accuracy reference source enables self adjustment of voltage, current and Clamp-on CT’s, long term accuracy assured
·           No load wiring detection; wiring examination for LV switchboard before opening
·            Double way of power supply via lithium battery or measured circuit
Technical data

General
 
Power supply
220V±20%
Power consumption
Measurement: 25VA, source ouput120VA
Ambient temperature
-20~50
Relative humidity (not condensing)
40%~95%
Dimension(D×W×H, mm)
400×320×160
Weight
10Kg
Warm-up time
10min
LCD color display
8”, 800×600 TFT
Communication port
RS232, USB
Output voltage
Measuring range
30V~400V with four internal ranges
(three phase three wire: 100V, 380V; three phase four wire: 57V, 220V)
Setting accuracy of voltage
0.05%
Distortion
≤1%
Capacity
≥10VA/position
Resolution for test voltage
0.01
Output current
Measuring range
Direct 0.01A~12A
5A clamp-on CT : 10mA~10A
100 A clamp-on CT: 1A~200A
Setting accuracy of current
Direct: 0.05%
5A clamp-on CT: 0.2%,
100 A clamp-on CT: 0.5%,
Distortion
≤1%
Capacity
10VA/position
Stability for test current
Direct: 0.05%
5A/100 A clamp-on CT: 0.1%
Output phase
Adjusting range
-180°~+180°
Adjusting fineness
0.01°
Output frequency
Adjusting range
45~65Hz
Adjusting fineness
0.01Hz
Monitoring
6digits displayed
Standard source
Voltage range
AC30V-400V
Accuracy of voltage
0.1%
Current range
0.01-10A
Accuracy of current
Direct: 0.1%
5A clamp-on CT: 0.2%
Error of active power/energy
Direct: 0.1%
5A clamp-on CT: 0.2%
100A clamp-on CT: 0.5%
Error of reactive power/energy
Direct: 0.1%
5A clamp-on CT: 0.2%
100A clamp-on CT: 0.5%
Error of apparent power/energy
Direct: 0.1%
5A clamp-on CT: 0.2%
100A clamp-on CT: 0.5%
Standard deviation estimates
≤0.02%
Phase differences
Voltage: ≤0.3
Current: ≤0.3
Reference time standard
Frequency: 1Hz, 500kHz (TTL level)
Stability: 2×10-8/day
Accuracy: 2×10-7

 